Product Model
vppm-6l-l-1-g18-0l2h-lk-s1

Key Features
- 1Regulates pressure from 0.02 bar to 2 bar with high accuracy.
- 2Supports IO-Link protocol for seamless data communication and control.
- 3Built with soft sealing principle and anodized aluminum alloy housing for durability.
- 4Includes reverse polarity protection and maintains output pressure unregulated in case of power supply interruption.
- 5Can be mounted with through-hole or accessories, offering flexibility in installation.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Nominal width pressurization | 6mm | Exhaust nominal width | 4.5mm |
| Actuation type | Electrical | Sealing principle | Soft |
| Mounting position | Any | Structural design | Pilot-controlled diaphragm regulator |
| Short-circuit protection | For all electrical connections | Safety instructions | VPPM safety position: if the supply cable breaks, the outlet pressure is maintained in uncontrolled form. |
| Symbol | 00995303 | Reverse polarity protection | for all electrical connections |
| Reset method | Mechanical spring | Type of control | Pilot-controlled |
| Valve function | 3-way proportional pressure control valve | Display type | LED |
| Pressure regulation range MPa | 0.002MPa 0.2MPa | Pressure regulation range | 0.02bar 2bar |
| Inlet pressure 1 | 0bar 4bar | Inlet pressure 1 MPa | 0MPa 0.4MPa |
| Max. pressure hysteresis | 0.01bar | Standard nominal flow rate | 380l/min |
| DC operating voltage range | 18V 30V | Max. current consumption | 300mA |
| Duty cycle | 100% | Max. electrical power consumption | 7W |
| Protocol | I-Port IO-Link? | Residual ripple | 10 % |
| Operating medium | Compressed air as per ISO 8573-1:2010 [7:4:4] Inert gas | Information on operating and pilot media | Operation with oil lubrication not possible |
| Certification | RCM compliance mark c UL us - Listed (OL) | KC characters | KC EMC |
| CE marking (see declaration of conformity) | As per EU EMC directive As per EU RoHS directive | UKCA marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions |
| Certificate issuing authority | UL E322346 | Corrosion resistance class (CRC) | 2 - Moderate corrosion stress |
| LABS (PWIS) conformity | VDMA24364-B1/B2-L | Temperature of medium | 10°C 50°C |
| Degree of protection | IP65 | Ambient temperature | 0°C 60°C |
| Product weight | 400g | Linearity | 1%FS |
| Hysteresis | 0.5%FS | Reproducibility | 0.5%FS |
| Overall accuracy | 1.25 %FS | Temperature coefficient | 0.04%/K |
| Repetition accuracy FS | 0.5% | IO-Link?, protocol version | Device V 1.1 |
| IO-Link?, communication mode | COM1 (4.8 kBd), COM2 (38.4 kBd), COM3 (230.4 kBd) | IO-Link?, port class | A |
| IO-Link?, process data width OUT | 2 Byte | IO-Link?, process data width IN | 2 Byte |
| IO-Link?, minimum cycle time | 0.5 ms | Type of mounting | Optionally: With through-hole With accessories |
| Pneumatic connection 1 | G1/8 | Pneumatic connection 2 | G1/8 |
| Pneumatic connection 3 | G1/8 | Note on materials | RoHS-compliant |
| Housing material | Wrought aluminum alloy Anodized | Manufacturer ID | 8024258 |
Specifications may be subject to change without notice