Product Model
236-502/000-006

Key Features
- 1Designed for Ex-i applications with CAGE CLAMP technology, ensuring secure and reliable connections.
- 2Push-in CAGE CLAMP for fast and time-saving termination of solid and ferruled conductors.
- 3Suitable for various conductor cross sections (0.08 - 2.5 mm²), including solid-core, fine-strand, and multi-wired conductors.
- 4Rated voltage of 630 V, suitable for demanding electrical applications.
- 5Made from thermoplastic insulation material with an inflammability class of V0 according to UL94, ensuring long-lasting performance.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Variants: | Other pole numbers | Clamping units | 2 |
| Total number of potentials | 2 | Number of connection types | 1 |
| Number of levels | 1 | Pin spacing | 7.5/7.62 mm / 0.295/0.3 inches |
| Width | 17.3 mm / 0.681 inches | Height | 17 mm / 0.669 inches |
| Height from the surface | 13 mm / 0.512 inches | Depth | 14 mm / 0.551 inches |
| Solder pin length | 4mm | Solder pin dimensions | 0.7 x 0.7 mm |
| Drilled hole diameter with tolerance | 1.1(+0.1)mm | PCB contact | THT |
| Solder pin arrangement | over the entire terminal strip (in-line) | Number of solder pins per potential | 2 |
| Note (material data) | Information on material specifications can be found here | Color | blue |
| Material group | I | Insulation material (main housing) | Polyamide (PA66) |
| Flammability class per UL94 | V0 | Clamping spring material | Chrome-nickel spring steel (CrNi) |
| Contact material | Electrolytic copper (ECu) | Contact plating | Tin |
| Fire load | 0.04MJ | Weight | 2.3g |
| Limit temperature range | -60 … +105 °C | Product Group | 4 (Printed Circuit Connectors) |
| ETIM 9.0 | EC002643 | ETIM 8.0 | EC002643 |
| ECCN | NO US CLASSIFICATION | PU (SPU) | 280 (70) pcs |
| Packaging type | Box | Country of origin | CH |
| GTIN | 4044918772129 | Customs tariff number | 85369010000 |
| RoHS Compliance Status | Compliant,No Exemption | Ratings per | IEC/EN 60664-1 |
| Rated voltage (III / 3) | 400V | Rated impulse voltage (III / 3) | 6kV |
| Rated voltage (III/2) | 630V | Rated surge voltage (III/2) | 6kV |
| Nominal voltage (II/2) | 1000V | Rated surge voltage (II/2) | 6kV |
| Rated current | 24A | Legend (ratings) | (III / 2) ? Overvoltage category III / Pollution degree 2 |
| Approvals per | CSA | Rated current UL (Use Group B) | 300A |
| Rated current UL (Use Group B), factory wiring only | 15A | Rated voltage UL (Use Group D) | 300V |
| Rated current UL (Use Group D) | 10A | Rated voltage CSA (Use Group B) | 300V |
| Rated current CSA (Use Group B) | 15A | Rated voltage CSA (Use Group D) | 300V |
| Rated current CSA (Use Group D) | 10A | Connection technology | CAGE CLAMP? |
| Actuation type | Operating tool | Solid conductor | 0.08 … 2.5 mm2 / 28 … 12 AWG |
| Fine-stranded conductor | 0.08 … 2.5 mm2 / 28 … 12 AWG | Fine-stranded conductor; with insulated ferrule | 0.25 … 1.5 mm2 |
| Fine-stranded conductor; with uninsulated ferrule | 0.25 … 1.5 mm2 | Note (conductor cross-section) | 12 AWG: THHN, THWN |
| Strip length | 5 … 6 mm / 0.2 … 0.24 inches | Conductor connection direction to PCB | 45° |
| Number of poles | 2 |
Specifications may be subject to change without notice