Product Model
2010-1203

Key Features
- 1DIN Rail Mounting: Designed for easy installation on DIN rail 35 x 15 and 35 x 7.5.
- 2Push-in CAGE CLAMP: Fast and secure wire termination with push-in technology.
- 3Ex e II Compliance: Suitable for hazardous environments with Ex e II certification.
- 4Side and Center Marking: Clear identification of terminals for easy wiring.
- 510 mm² Conductor Area: Supports conductors up to 10 mm² for robust connections.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Clamping units | 2 | Total number of potentials | 1 |
| Number of levels | 1 | Number of jumper slots | 2 |
| Width | 10 mm / 0.394 inches | Height | 67.8 mm / 2.669 inches |
| Depth from upper-edge of DIN-rail | 36.9 mm / 1.453 inches | Depth | 43.5 mm / 1.713 inches |
| Mounting type | DIN-35 rail | Marking level | Center/side marking |
| Note (material data) | Information on material specifications can be found here | Color | red |
| Material group | I | Insulation material (main housing) | Polyamide (PA66) |
| Flammability class per UL94 | V0 | Fire load | 0.329MJ |
| Weight | 17.3g | Processing temperature | -35 … +85 °C |
| Continuous operating temperature | -60 … +105 °C | Product Group | 22 (TOPJOB S) |
| ECCN | NO US CLASSIFICATION | PU (SPU) | 25 pcs |
| Packaging type | Box | Country of origin | DE |
| GTIN | 4045454290696 | Customs tariff number | 85369010000 |
| RoHS Compliance Status | Compliant,No Exemption | Ratings per | ATEX: PTB 05 ATEX 1070 U / IECEx: PTB 06.0003U (Ex eb IIC Gb) |
| Rated voltage (III / 3) | 800V | Rated impulse voltage (III / 3) | 8kV |
| Rated current | 57A | Current at conductor cross-section (max.) mm2 | 76A |
| Legend (ratings) | (III / 3) ? Overvoltage category III / Pollution degree 3 | Approvals per | CSA 22.2 No 158 |
| Rated voltage UL (Use Group B) | 600V | Rated current UL (Use Group B) | 65A |
| Rated voltage UL (Use Group C) | 600V | Rated current UL (Use Group C) | 65A |
| Rated voltage CSA (Use Group B) | 600V | Rated current CSA (Use Group B) | 65A |
| Rated voltage CSA (Use Group C) | 600V | Rated current CSA (Use Group C) | 65A |
| Reference hazardous areas | See application instructions in section “Knowledge andDownloads – Documentation – Additional Information: Technical Section; Technical Explications” | Rated voltage EN (Ex e II) | 550V |
| Rated current (Ex e II) | 51A | Power loss, per pole (potential) | 1.819W |
| Rated current I<sub>N</sub> for specified power loss | 57A | Resistance value for specified, current-dependent power loss | 0.001Ω |
| Connection technology | Push-in CAGE CLAMP? | Actuation type | Operating tool |
| Connectable conductor materials | Copper | Nominal cross-section | 10 mm2 |
| Solid conductor | 0.5 … 16 mm2 / 20 … 6 AWG | Solid conductor; push-in termination | 4 … 16 mm2 / 14 … 6 AWG |
| Fine-stranded conductor | 0.5 … 16 mm2 / 20 … 6 AWG | Fine-stranded conductor; with insulated ferrule | 0.5 … 10 mm2 / 20 … 8 AWG |
| Fine-stranded conductor; with ferrule; push-in termination | 4 … 10 mm2 / 12 … 8 AWG | Note (conductor cross-section) | Depending on the conductor characteristic, a conductor with a smaller cross-section can also be inserted via push-in termination.AWG specifications were converted according to IEC. |
| Strip length | 17 … 19 mm / 0.67 … 0.75 inches | Wiring direction | Front-entry wiring |
Specifications may be subject to change without notice