Key Features
- 1Insulated 2-way jumper for reliable connections.
- 2Rated current of 30A for high-performance applications.
- 3Available in vibrant orange color for easy identification.
- 4Compatible with WAGO TOPJOB S Series rail mount terminal blocks.
- 5Compliant with RoHS and phthalates regulations for environmental safety.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Width | 15.2 mm / 0.598 inches | Depth | 13 mm / 0.512 inches |
| Jumper assignment | 1-2 | Note (material data) | Information on material specifications can be found here |
| Color | orange | Fire load | 0.012MJ |
| Weight | 1.9g | Product Group | 22 (TOPJOB S) |
| eCl@ss 10.0 | 27-14-11-40 | eCl@ss 9.0 | 27-14-11-40 |
| ETIM 9.0 | EC000489 | ETIM 8.0 | EC000489 |
| ECCN | NO US CLASSIFICATION | PU (SPU) | 50?(10)?pcs |
| Packaging type | box | Country of origin | DE |
| GTIN | 4050821448136 | Customs tariff number | 8536698000 |
| RoHS Compliance Status | Compliant,No Exemption | Rated voltage (III / 3) | 500V |
| Rated current | 30A | Test specification <br/>Railway applications – <br/>Rolling stock – <br/>Electronic equipment | DIN EN 50155 (VDE 0115-200):2022-06 |
| Test procedure <br/>Railway applications – <br/>Rolling stock equipment – <br/>Shock and vibration tests | DIN EN 61373 (VDE 0115-0106):2011-04 | Spectrum/Installation location | Service life test, Category?1, Class?A/B |
| Function test with noise-like vibration | Test passed according to Section 8 of the standard | Frequency | f1= 5 Hz to f2= 150 Hz |
| Acceleration | 5g (highest test level used for all axes) | Test duration per axis | 5 h |
| Test directions | X, Y and Z axes | Monitoring for contact faults/interruptions | Passed |
| Voltage drop measurement before and after each axis | Passed | Simulated service life test through increased levels of noise-like vibration | Test passed according to Section 9 of the standard |
| Extended test scope: Monitoring for contact faults/interruptions | Passed | Extended test scope: Voltage drop measurement before and after each axis | Passed |
| Shock test | Test passed according to Section 10 of the standard | Shock form | Half sine |
| Shock duration | 30 ms | Number of shocks per axis | 3 pos. und 3 neg. |
| Vibration and shock stress for rolling stock equipment | Passed |