Product Model
IMB08-02BPSVC0S

Key Features
- 12 to 4 mm for precise detection in various conditions.
- 2Rugged stainless steel housing with plastic sensing face for durability.
- 3Compatible with IO-Link for enhanced communication and flexibility in automation applications.
- 4Visual installation aid and self-locking nuts simplify setup and reduce errors.
- 5Resistant to oils, cooling lubricants, and suitable for outdoor use with IP 68/69K rating.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Housing | Metric | Housing | Standard design |
| Thread size | M8 x 1 | Diameter | Ø 8 mm |
| Sensing range Sn | 2 mm | Safe sensing range Sa | 1.62 mm |
| Installation type | Flush | Switching frequency | 4,000 Hz |
| Connection type | Male connector M12, 4-pin | Switching output | PNP |
| Output function | NO | Electrical wiring | DC 3-wire |
| Enclosure rating | IP682)#!#IP69K3) | Special features | Resistant against coolant lubricants, Visual adjustment indicator, IO-Link, Temperature resistance |
| Special applications | Zones with coolants and lubricants, Mobile machines, Difficult application conditions | Items supplied | Mounting nut, V2A stainless steel, with locking teeth (2x) |
| Supply voltage | 10 V DC ... 30 V DC | Ripple | ≤ 10 % |
| Voltage drop | ≤ 2 V | Hysteresis | 3 % ... 20 % |
| Reproducibility | ≤ 2 % | Temperature drift (of Sr) | ± 10 % |
| EMC | According to EN 60947-5-2 | Continuous current Ia | ≤ 200 mA |
| No load current | ≤ 10 mA | Short-circuit protection | ✔ |
| Power-up pulse protection | ✔ | Shock and vibration resistance | 100 g / 11 ms / 1000 cycles; 150 g / 1 Mio cycles; 10 Hz ... 55 Hz, 1 mm / 55 Hz ... 500 Hz / 15 g |
| Ambient operating temperature | –40 °C ... +100 °C | Housing material | Stainless steel V2A, DIN 1.4305 / AISI 303 |
| Sensing face material | Plastic, LCP | Housing length | 60 mm |
| Thread length | 32 mm | Tightening torque, max. | Typ. 7 Nm4)#!#Typ. 14 Nm5) |
| Protection class | III | UL File No. | E181493 |
| Communication interface | IO-Link V1.0 | Communication Interface detail | COM2 (38,4 kBaud) |
| Process data length | 1 Byte | Process data structure | Bit 0 = Sr reached#!#Bit 1 = Sa reached |
| Note | The values are reference values which may vary | St37 steel (Fe) | 1 |
| Stainless steel (V2A, 304) | Approx. 0.74 | Aluminum (Al) | Approx. 0.43 |
| Copper (Cu) | Approx. 0.33 | Brass (Br) | Approx. 0.46 |
| Remark | Associated graphic see "Installation" | B | 6.5 mm |
| C | 8 mm | D | 6 mm |
| F | 16 mm |