Product Model
CMB30-25NPPEW2SA00

Key Features
- 1Non-Contact Detection: Detects objects and levels without physical contact, suitable for metallic and non-metallic materials.
- 2High Sensing Range: Offers a sensing range of up to 25 mm, ensuring reliable detection in various applications.
- 3DC 4-Wire Electrical Wiring: Compatible with DC 4-wire electrical wiring for easy integration into your system.
- 4PNP Output Function: Provides a PNP output function for clear signal indication in your automation setup.
- 5IP67, IP68, IP69K Enclosure Rating: Ensures high protection against dust and water, making it durable for industrial environments.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Housing | Metric | Thread size | M30 x 1.5 |
| Diameter | Ø 30 mm | Sensing range Sn | 0 mm ... 25 mm |
| Safe sensing range Sa | 19.13 mm | Installation type | Non-flush |
| Switching frequency | 50 Hz | Connection type | Cable, 4-wire, 2 m |
| Switching output | PNP | Output function | Complementary |
| Output characteristic | Wire configurable | Electrical wiring | DC 4-wire |
| Adjustment_Potentiometer | Sensitivity (11 turns) | Adjustment_Wire/pin | Sensitivity |
| Adjustment_IO-Link | Sensitivity, sensor parameters and Smart Task functions | Enclosure rating | IP67#!#IP683)#!#IP69K |
| Special features | Visual adjustment indicator, Smart Task, IO-Link | Pin 2 configuration | External input, Teach-in, switching signal |
| Items supplied | Mounting nut, PA12 plastic (2x)#!#Screwdriver for potentiometer adjustment (1 x) | Supply voltage | 10 V DC ... 36 V DC |
| Ripple | ≤ 10 % | Voltage drop | ≤ 2 V DC |
| Current consumption | ≤ 20 mA | Time delay before availability | ≤ 300 ms |
| Hysteresis | 3 % ... 20 % | Reproducibility | ≤ 5 % |
| Temperature drift (of Sr) | ± 10 % | EMC | EN 61000-4-2 ESD: > 40 kV CD and AD#!#EN 61000-4-3 Radiated RF: 20 V/m#!#EN 61000-4-4 burst: +/- 4 kV / 5 kHz#!#EN 61000-4-5 Surge: Voltage supply > 2 kV with 500 ohm; switching output > 2 kV with 500 ohm#!#EN 61000-4-6 HF: > 20 Vrms#!#EN 61000-4-8 mains frequency magnetic fields: Permanent > 60 A/m, 75,9 µ tesla; briefly > 600 A/m, 759 µ tesla |
| Continuous current Ia | ≤ 200 mA | Cable material | PVC |
| Conductor size | 0.34 mm² | Cable diameter | Ø 5.2 mm |
| Short-circuit protection | ✔ | Power-up pulse protection | ✔ |
| Shock and vibration resistance | EN 60068-2-27 shock resistance Ea: 30 g 11 ms; 3 shocks in each direction of the 3 coordinate axes#!#IEC 60068-2-31 drop test: 2 times from 1 m, 100 times from 0.5 m#!#EN 60068-2-6 vibration resistance Fc: 10 Hz ... 150 Hz, 1 mm / 15 g | Ambient operating temperature | –30 °C ... +85 °C |
| Ambient temperature, storage | –40 °C ... +85 °C | Housing material | Plastic, PBT |
| Housing length | 81 mm | Thread length | 45.5 mm |
| Tightening torque, max. | ≤ 7.5 Nm | UL File No. | NRKH.E191603 |
| Communication interface | IO-Link V1.1 | Communication Interface detail | COM2 (38,4 kBaud) |
| Cycle time | > 5 ms | Process data length | 4 Byte |
| Process data structure | Bit 0 = switching signal QL1#!#Bit 1 = switching signal QL2#!#Bit 2 = Sensor switching channel Qint1#!#Bit 3 = Sensor switching channel Qint2#!#Bit 4 = Contamination alarm for switching channel Qint1#!#Bit 5 = Contamination channel for Qint2#!#Bit 6 = Temperature alarm#!#Bit 7 = Short-circuit#!#Bit 16 ... 31 = Analog value (digit value, not linearized) | Note | The values are reference values which may vary |
| Metal | 1 | Water | 1 |
| PVC | Approx. 0.4 | Oil | Approx. 0.25 |
| Glass | 0.6 | Ceramics | 0.5 |
| Alcohol | 0.7 | Wood | 0.2 ... 0.7 |
| Remark | Associated graphic see "Installation" | A | 30 mm |
| B | 60 mm | C | 30 mm |
| D | 75 mm | E | 14.5 mm#!#In critical distances, the sensor should be tested in the application |
| F | 75 mm | Smart Task name | Base logics |
| Logic function | Direct#!#AND#!#OR#!#Window#!#Hysteresis | Timer function | Deactivated#!#Switch-on delay#!#Off delay#!#ON and OFF delay#!#Impulse (one shot) |
| Inverter | Yes | Switching signal_Switching signal QL1 | Switching output |
| Switching signal_Switching signal QL2 | Switching output |
Specifications may be subject to change without notice