Key Features
- 1High reliability and durability for motor control applications.
- 2Low sealed consumption 24V DC coil for efficient operation.
- 3Certified to multiple international standards (IEC, UL, CSA, CCC, EAC).
- 4Easy installation and maintenance with a drawer-mounted coil.
- 5Suitable for high operating rates up to 2400 cycles/hour in environments up to 55°C.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
| Parameter | Value | Parameter | Value | 
|---|---|---|---|
| Range | TeSys | Range of Product | TeSys F | 
| Product or Component Type | Contactor | Device short name | LC1F | 
| Contactor application | Resistive load<br />Motor control | Utilisation category | AC-1<br />AC-4<br />AC-3 | 
| Poles description | 3P | [Ue] rated operational voltage | <= 460 V DC<br /><= 690 V AC 50/60 Hz | 
| [Uc] control circuit voltage | 24 V DC | [Ie] rated operational current | 315 A (at <104 °F (40 °C)) at <= 440 V AC-1<br />225 A (at <131 °F (55 °C)) at <= 440 V AC-3 | 
| [Uimp] rated impulse withstand voltage | 8 kV | [Ith] conventional free air thermal current | 315 A (at 104 °F (40 °C)) | 
| Rated breaking capacity | 1800 A conforming to IEC 60947-4-1 | [Icw] rated short-time withstand current | 1800 A 104 °F (40 °C) - 10 s<br />1000 A 104 °F (40 °C) - 30 s<br />850 A 104 °F (40 °C) - 1 min<br />560 A 104 °F (40 °C) - 3 min<br />440 A 104 °F (40 °C) - 10 min | 
| Associated fuse rating | 315 A gG at <= 440 V<br />250 A aM at <= 440 V | Average impedance | 0.32 mOhm - Ith 315 A 50 Hz | 
| [Ui] rated insulation voltage | 1000 V IEC 60947-4-1<br /> 1500 V VDE 0110 group C | Power dissipation per pole | 32 W AC-1<br />16 W AC-3 | 
| Overvoltage category | III | power pole contact composition | 3 NO | 
| Motor power kW | 110 kW at 380...400 V AC 50/60 Hz (AC-3)<br />110 kW at 415 V AC 50/60 Hz (AC-3)<br />110 kW at 440 V AC 50/60 Hz (AC-3)<br />129 kW at 500 V AC 50/60 Hz (AC-3)<br />129 kW at 660...690 V AC 50/60 Hz (AC-3)<br />63 kW at 220...230 V AC 50/60 Hz (AC-3)<br />40 kW at 400 V AC 50/60 Hz (AC-4) | Control circuit voltage limits | Operational 0.85...1.1 Uc 131 °F (55 °C))<br />Drop-out 0.15...0.2 Uc 131 °F (55 °C)) | 
| Mechanical durability | 10 Mcycles | Inrush power in W | 800 W 68 °F (20 °C)) | 
| Hold-in power consumption in W | 5 W 68 °F (20 °C) | Maximum operating rate | 2400 cyc/h 131 °F (55 °C) | 
| Operating time | 30...40 ms closing<br />30...50 ms opening | Connections - terminals | Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)flexible without cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)flexible with cable end<br />Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)flexible with cable end<br />Control circuit screw clamp terminals 1 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Control circuit screw clamp terminals 2 0.002…0.006 in² (1…4 mm²)solid without cable end<br />Power circuit bar 2 32 x 4 mm<br />Power circuit lugs-ring terminals 1 0.3 in² (185 mm²)<br />Power circuit connector 1 0.3 in² (185 mm²)<br />Power circuit bolted connection | 
| Tightening torque | Control circuit 10.6 lbf.in (1.2 N.m)<br />Power circuit 309.8 lbf.in (35 N.m) | Mounting Support | Plate | 
| Heat dissipation | 5 W | motor power range | 55…100 kW 200…240 V 3 phase<br />110…220 kW 480…500 V 3 phase<br />110…220 kW 380…440 V 3 phase | 
| Motor starter type | Direct on-line contactor | Contactor coil voltage | 24 V DC standard | 
| Standards | IEC 60947-4-1<br />EN 60947-4-1<br />JIS C8201-4-1<br />EN 60947-1<br />IEC 60947-1 | Product Certifications | CB<br />DNV<br />BV<br />ABS<br />UL<br />CSA<br />RMRoS<br />RINA<br />LROS (Lloyds register of shipping)<br />UKCA | 
| compatibility code | LC1F | Control circuit type | DC standard | 
| IP degree of protection | IP20 front face with shrouds IEC 60529<br />IP20 front face with shrouds VDE 0106 | Protective treatment | TH | 
| Ambient Air Temperature for Operation | 23…131 °F (-5…55 °C) | Ambient Air Temperature for Storage | -76…176 °F (-60…80 °C) | 
| Permissible ambient air temperature around the device | -40…158 °F (-40…70 °C) | Height | 7.8 in (197 mm) | 
| Width | 6.6 in (168.5 mm) | Depth | 7.1 in (181 mm) | 
| Operating altitude | 9842.52 ft (3000 m) without derating | Net Weight | 10.47 lb(US) (4.75 kg) | 
Specifications may be subject to change without notice