Product Model
150-C3NCD

Key Features
- 11. Efficient Motor Control: The Allen-Bradley 150-C3NCD offers precise control over your motors, ensuring optimal performance and efficiency in your industrial applications.;
- 22. Wide Voltage Compatibility: Operating on 100-240V AC, this smart motor controller is versatile and can be easily integrated into various systems.;
- 33. Reliable Performance: Built with high-quality components, the 150-C3NCD provides reliable performance, reducing downtime and increasing productivity.;
- 44. Easy Integration: Designed for 3-phase applications, this controller is straightforward to set up and integrate into your existing control systems.;
- 55. Smart Technology: Equipped with advanced smart technology, the 150-C3NCD offers real-time monitoring and control, enhancing your motor control capabilities.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Dimension Unit | CM | Weight Unit | KG |
| Stock Status | NON_STOCKED | Dimension Length | 18.491 |
| Dimension Width | 9.398 | Lead Time | 5 |
| Dimension Height | 17.602 | Quick Turnaround | false |
| Preferred Availability | false | Repairable | NOT_REPAIRABLE |
| Enclosure | Open type | Number of poles | Equipment is designed for 3-phase only for power circuit |
| Mounting hole size | 4.6 mm | Pollution degree | 2 |
| Altitude | 2000 m | EMC immunity levels | Surge transient: per EN/IEC 60947-4-2 per IEC |
| EMC emission levels | Radiated emission: Class A per IEC | Operating temperature | Open: -5 to 50 °C (23 to 122 °F) |
| Humidity | 5...95% noncondensing | Rated surrounding temperature range without derating | -5 °C |
| Storage and transportation temperature | -25 °C | Steady state heat dissipation | 11 W |
| Selectable soft stop | Off, 100%, 200%, or 300% of the start time setting when wired | Selectable initial torque | 15%, 25%, 35%, and 65% of locked rotor torque |
| Selectable kick start - 450% FLA | 0, 0.5, 1.0, or 1.5 s | Function | Single direction |
| Internal bypass | Yes | Tightening torque | 2.3...3.4 Nm (30 in-lb) for line power terminals, 4.0 Nm (35 in-lb) if 25 mm2 (4 AWG) wire in top terminal for line power terminal |
| Break | TB-97, -98 (OVLD/Fault): 72VA for auxiliary contacts | Make | TB-97, -98 (OVLD/Fault): 432VA for auxiliary contacts |
| Vibration | Opsal: 1.0 G peak, 0.15 mm (0.006 in) displacement | Cable size | 2.5...25 mm2 (14...4 AWG) for line power terminals |
| Height | 139.7 mm (5.5 in) | Depth | 110 mm (4.33 in) |
| Width | 44.8 mm (1.76 in) | Shock | Opsal: 15 G |
| Weight | 1.009 | Degree of protection (IP) | IP2X |
| Input ON-state current (IN1, IN2) | 9.8mA @ 120V AC/19.6mA @ 240V AC for control circuit, 7.3mA @ 24V AC/DC for control circuit | Rated control power during start without fan | 205mA @ 120V AC/145mA @ 240V AC, 705mA @ 24V DC/580mA @ 24V AC |
| Input ON-state voltage, during start (IN1, IN2) | 85V AC @ 19.2V DC/19.2V AC minimum for control circuit | Selectable current limit | 150%, 250%, 350%, and 450% of full load current |
| Input OFF-state voltage (IN1, IN2), max | 40V AC @ 17V DC/12V AC for control circuit | Selectable start times | 2, 5, 10, 15, 20, 25, or 30 s |
| Selectable overload trip class | Trip Class 10, 15, or 20 | Short circuit protection device performance (SCPD) type | Type 1 |
| Integrated motor overload protection | Yes | Standard available fault current, max | 5 kA @ maximum standard fuse 15 A for delta device opsal current rating |
| Standard controller feature | Soft stop | Rated operational current, max | TB-97, -98 (OVLD/Fault): 0.6A @ 120V AC and 0.3A @ 240V AC for auxiliary contacts |
| Utilization category | TB-23, -24 (normal/up-to-speed), TB-33, -34 (normal/up-to-speed): C300/R150 per UL/CSA/NEMA for Side mount auxiliary contacts | Type of contacts | TB-97, -98 (OVLD/Fault): Normally Open (N.O.) for auxiliary contacts |
| Type of control circuit | TB-97, -98 (OVLD/Fault): Electromagnetic relay for auxiliary contacts | Conventional thermal current (Ith) | TB-97, -98 (OVLD/Fault): 1 A for auxiliary contacts |
| Type of current | TB-97, -98 (OVLD/Fault): AC/DC for auxiliary contacts | High capacity available fault current, max | 69kA @ 600V, maximum current 10 A time delay Class J or Class L fuse for inside delta connected motors |
| Number of contacts | TB-97, -98 (OVLD/Fault): 1 for auxiliary contacts | Short-circuit protection device list | Non-time delay Thermal magnetic circuit breaker High capacity time delay class CC/J/L |
| Input OFF-state current | <10 mA, <12 mA @ input off-state voltage (IN1, IN2) for control circuit | Rated control power during start with fan | 215mA @ 120V AC/180mA @ 240V AC, 800mA @ 24V DC/660mA @ 24V AC |
| Rated operational voltage | 250V AC/30V DC per UL/CSA/NEMA for Side mount auxiliary contacts | Insulation voltage | Rated 600V AC per UL/CSA/NEMA for power circuit |
| Delta connected motor current | 1.7...5.1A @ 500/575V AC, 3-phase | Line connected motor current | 1...3A @ 500/575V AC, 3-phase |
| Dielectric withstand | 2500V AC per IEC for power circuit | Rated impulse voltage | 6 kV for power circuit |
| Overvoltage category | III per IEC for side mount auxiliary contacts | Delta connected motor power, max | 1...3Hp @ 575V AC, 60 Hz, 3-phase |
| Line connected motor power, max | 1.5 kW @ 500V AC @ 50Hz, 3-phase | Operating frequency | 50/60 Hz per UL/CSA/NEMA for power circuit |
| Repetitive peak voltage | 1600V per UL/CSA/NEMA for power circuit | DV/DT protection | 1000V/μs for power circuit |
| Controller type | SMC-3 | Overload current | 1 A |
| Rated control supply voltage at AC 60 Hz | 100 | Rated control supply voltage at AC 50 Hz | 100 |
| Rated operating voltage Ue | 200 | Voltage type for actuating | AC/DC |
| With display | No |