Product Model
UTT 2,5-2MT-P/P BU

Key Features
- 1Double level feed through for efficient wiring.
- 2Screw termination with test socket screws for easy testing.
- 3Lever-type disconnect knife for convenient circuit separation.
- 4Supports large surface labeling for clear identification.
- 5RoHS compliant with UL, cUL, EAC, CSA approvals.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Product type | Disconnect terminal block | Number of connections | 4 |
| Number of rows | 2 | Potentials | 2 |
| Article revision | 05 | Overvoltage category | III |
| Degree of pollution | 3 | Rated surge voltage | 6 kV |
| Maximum power dissipation for nominal condition | 0.77 W | Number of connections per level | 2 |
| Nominal cross section | 2.5 mm² | Screw thread | M3 |
| Tightening torque | 0.5 ... 0.6 Nm | Stripping length | 9 mm |
| Internal cylindrical gage | A3 | Connection in acc. with standard | IEC 60947-7-1 |
| Conductor cross section rigid | 0.14 mm² ... 4 mm² | Cross section AWG | 26 ... 12 (converted acc. to IEC) |
| Conductor cross section flexible | 0.14 mm² ... 4 mm² | Conductor cross section, flexible [AWG] | 26 ... 12 (converted acc. to IEC) |
| Conductor cross-section flexible (ferrule without plastic sleeve) | 0.14 mm² ... 2.5 mm² | Flexible conductor cross section (ferrule with plastic sleeve) | 0.14 mm² ... 2.5 mm² |
| 2 conductors with same cross section, solid | 0.14 mm² ... 1.5 mm² | 2 conductors with same cross section, flexible | 0.14 mm² ... 1.5 mm² |
| 2 conductors with same cross section, flexible, with ferrule without plastic sleeve | 0.14 mm² ... 1.5 mm² | 2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve | 0.5 mm² ... 1.5 mm² |
| Nominal current | 16 A | Maximum load current | 16 A (in case of a 4 mm² conductor cross section, the maximum load current must not be exceeded by the total current of all connected conductors.) |
| Nominal voltage | 400 V | Nominal cross section | 2.5 mm² |
| Screw thread | M3 | Internal cylindrical gage | A3 |
| Connection in acc. with standard | IEC 60947-7-1 | Conductor cross section rigid | 0.14 mm² ... 4 mm² |
| Cross section AWG | 26 ... 12 (converted acc. to IEC) | Conductor cross section flexible | 0.14 mm² ... 4 mm² |
| Conductor cross section, flexible [AWG] | 26 ... 12 (converted acc. to IEC) | Conductor cross-section flexible (ferrule without plastic sleeve) | 0.14 mm² ... 2.5 mm² |
| Flexible conductor cross section (ferrule with plastic sleeve) | 0.14 mm² ... 2.5 mm² | 2 conductors with same cross section, solid | 0.14 mm² ... 1.5 mm² |
| 2 conductors with same cross section, flexible | 0.14 mm² ... 1.5 mm² | Nominal current | 16 A |
| Maximum load current | 16 A (in case of a 4 mm² conductor cross section, the maximum load current must not be exceeded by the total current of all connected conductors.) | Nominal voltage | 400 V |
| Nominal cross section | 2.5 mm² | Width | 5.2 mm |
| End cover width | 2.2 mm | Height | 80.1 mm |
| Depth | 64.4 mm | Depth on NS 35/7,5 | 65 mm |
| Depth on NS 35/15 | 72.5 mm | Color | blue (RAL 5015) |
| Flammability rating according to UL 94 | V0 | Insulating material group | I |
| Insulating material | PA | Static insulating material application in cold | -60 °C |
| Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) | 125 °C | Relative insulation material temperature index (Elec., UL 746 B) | 130 °C |
| Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 3 | Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 3 |
| Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 3 | Fire protection for rail vehicles (DIN EN 45545-2) R26 | HL 1 - HL 3 |
| Calorimetric heat release NFPA 130 (ASTM E 1354) | 27,5 MJ/kg | Surface flammability NFPA 130 (ASTM E 162) | passed |
| Specific optical density of smoke NFPA 130 (ASTM E 662) | passed | Smoke gas toxicity NFPA 130 (SMP 800C) | passed |
| Open side panel | Yes | Ambient temperature (operation) | -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.) |
| Ambient temperature (storage/transport) | -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C) | Ambient temperature (assembly) | -5 °C ... 70 °C |
| Ambient temperature (actuation) | -5 °C ... 70 °C | Permissible humidity (operation) | 20 % ... 90 % |
| Permissible humidity (storage/transport) | 30 % ... 70 % | Connection in acc. with standard | IEC 60947-7-1
IEC 60947-7-1 |
| Mounting type | NS 35/7,5
NS 35/15 |
Specifications may be subject to change without notice
