Product Model
MINI MCR-SL-TC-UI-NC

Key Features
- 13-way electrical isolation for safe operation.
- 2Configurable via DIP switches for custom settings.
- 3Supports various thermocouple types (B, E, J, K, N, R, S, T, L, U, A-1, A-2, A-3, M).
- 4Output signals include 0...20 mA, 4...20 mA, 0...10 V, and more.
- 5Compact design with dimensions of 6.2 mm wide and 93.1 mm high.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| EMC note | EMC: class A product, see manufacturer's declaration in the download area | Product type | Temperature transmitter |
| Product family | MINI Analog | No. of channels | 1 |
| Overvoltage category | II | Pollution degree | 2 |
| Rated insulation voltage | 50 V AC/DC | Electrical isolation | Basic insulation in accordance with EN 61010 |
| Typical cold point errors | < 2 K | Cold point error, max. | < 3 K |
| Maximum power dissipation for nominal condition | 235.5 mW | Test voltage, input/output/supply | 1.5 kV AC (50 Hz, 60 s) |
| Protective circuit | Transient protection | Step response (0–99%) | < 30 ms |
| Maximum temperature coefficient | < 0.02 %/K | Transmission error in the set measuring range | ((150 K / set measurement range [K]) + 0.1)% |
| Transmission error in the full measuring range | ≤ 0,2 % | Nominal supply voltage | 24 V DC |
| Supply voltage range | 19.2 V DC ... 30 V DC (The DIN rail connector (ME 6,2 TBUS-2 1,5/5-ST-3,81 GN, item no. 2869728) can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail in accordance with EN 60715) | Max. current consumption | < 25 mA (at 24 V DC) |
| Power consumption | < 500 mW | Number of inputs | 1 |
| Input signal | Temperature | Sensor types that can be used (TC) | Thermocouples type J, K (IEC 584-1) |
| Temperature measuring range | min. 50 K | Sensor type: | -150 °C ... 1200 °C (configurable)
-150 °C ... 1350 °C |
| Number of outputs | 1 | Voltage output signal | 0 V ... 10 V
10 V ... 0 V
0 V ... 5 V
1 V ... 5 V |
| Max. voltage output signal | 12.5 V | Non-load voltage | approx. 12.5 V |
| Current output signal | 0 mA ... 20 mA
4 mA ... 20 mA
20 mA ... 0 mA
20 mA ... 4 mA | Max. current output signal | 23 mA |
| Short-circuit current | approx. 10 mA | Load/output load voltage output | ≥ 10 kΩ |
| Load/output load current output | < 500 Ω (at 20 mA) | Ripple | < 20 mV
< 20 mV |
| Connection method | Screw connection | Stripping length | 12 mm |
| Screw thread | M3 | Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² | Conductor cross section AWG | 26 ... 12 |
| Width | 6.2 mm | Height | 93.1 mm |
| Depth | 102.5 mm | Color | green (RAL 6021) |
| Housing material | PBT | Fire protection for rail vehicles (DIN EN 45545-2) R22 | HL 1 - HL 2 |
| Fire protection for rail vehicles (DIN EN 45545-2) R23 | HL 1 - HL 2 | Fire protection for rail vehicles (DIN EN 45545-2) R24 | HL 1 - HL 2 |
| Degree of protection | IP20 | Ambient temperature (operation) | -20 °C ... 65 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C | Certificate | CE-compliant |
| Identification | II 3 G Ex nA IIC T4 Gc X | Identification | UL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5 |
| Identification | GL EMC 2 D | Electromagnetic compatibility | Conformance with EMC directive |
| Noise immunity | EN 61000-6-2 | Note | When being exposed to interference, there may be minimal deviations. |
| Noise emission | EN 61000-6-4 | Standards/regulations | EN 61000-4-2 |
| Comments | Safety measures must be taken to prevent electrostatic discharge. | Designation | Electromagnetic RF field |
| Standards/regulations | EN 61000-4-3 | Typical deviation from the measuring range final value | 10 % |
| Designation | Fast transients (burst) | Standards/regulations | EN 61000-4-4 |
| Typical deviation from the measuring range final value | 10 % | Standards/regulations | EN 61000-4-5 |
| Comments | Criterion B | Designation | Conducted interferences |
| Standards/regulations | EN 61000-4-6 | Typical deviation from the measuring range final value | 10 % |
| Electrical isolation | Basic insulation in accordance with EN 61010 | Mounting type | DIN rail mounting |
| Assembly note | The DIN rail connector can be used for bridging the supply voltage. It can be snapped onto a 35 mm EN 60715 DIN rail. | Mounting position | any |
Specifications may be subject to change without notice