Product Model
MCR-FL-TS-LP-I-EX-400

Key Features
- 1High Precision Measurement: Measures temperature with accuracy, suitable for a wide range of industrial applications.
- 2HART Compatibility: Configurable via software with HART protocol for easy integration and control.
- 3Robust Safety Features: Designed for Ex ia IIC environments, ensuring safe operation in hazardous zones.
- 4Loop-Powered Design: Self-powered, reducing the need for external power sources and simplifying installation.
- 5Versatile Sensor Support: Compatible with resistance thermometers, thermocouples, and linear mV signals, offering flexibility in sensor choice.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Product type | Temperature transmitter | Application | Temperature |
| Article revision | 07 | Switch-on delay | 4 s |
| Line monitoring | NE 43 | Test voltage input/output | 2 kV AC (50 Hz, 60 s) |
| Step response (10-90%) | < 2 s | Transmission error voltage sensor | ±20 µV (-10 mV ... 100 mV) |
| Transmission error thermocouples | typ. 0.5 K (K, J, T, E, L, U), 1.0 K (N, C, D), 2.0 K (S, B, R) | Transmission error resistance-type sensor | ±0.1 Ω (10 ... 400 Ω), ±1.5 Ω (10 ... 2000 Ω) |
| Transmission error resistance thermometer | 0.2 K (Pt 100, Ni 100), 0.5 K (Pt 500, Ni 500), 0.3 K (Pt 1000, Ni 1000) | Input signal | Temperature |
| Configurable/programmable | no, preconfigured | Sensor types (RTD) that can be used | Pt, Ni (100, 500, 1000); min. measurement range 10 K |
| Sensor types that can be used (TC) | B, C, D, E, J, K, L, N, R, S, T, U; min. measurement range 50 K/500 K | Temperature measuring range | -25 °C ... 400 °C |
| Linear resistance measuring range | 10 Ω ... 400 Ω (min. measurement range 10 Ω) | Linear mV signal range | -10 mV ... 100 mV (min. measurement range 5 mV) |
| Configurable/programmable | no | Output description | Current output |
| Configurable/programmable | no | Current output signal | 4 mA ... 20 mA
20 mA ... 4 mA |
| Max. current output signal | ≤ 23 mA | Output current with short-circuit | ≤ 3.6 mA or ≥ 21 mA (adjustable, not for thermocouples) |
| Output current with wire break | ≤ 3.6 mA or ≥ 21 mA (adjustable) | Output current range with overrange/underrange | 3.8 mA ... 20.5 mA |
| Load/output load current output | ≤ 520 Ω (At U | Connection method | Pluggable screw connection |
| Stripping length | 8 mm | Screw thread | M3 |
| Conductor cross section rigid | 0.2 mm² ... 2.5 mm² | Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG | 24 ... 14 | Tightening torque | 0.5 Nm ... 0.6 Nm |
| Width | 12.5 mm | Height | 99 mm |
| Depth | 114.5 mm | Color | green (RAL 6021) |
| Flammability rating according to UL 94 | V0 | Housing material | Polyamide PA non-reinforced |
| Degree of protection | IP20 | Ambient temperature (operation) | -40 °C ... 55 °C |
| Certificate | CE-compliant | Standards/regulations | NAMUR recommendation NE 21 |
| Mounting type | DIN rail mounting | Mounting position | any |
Specifications may be subject to change without notice