Product Model
IL IB BK-PAC

Key Features
- 1Efficient Inline Connectivity: Connects up to 63 Inline devices seamlessly.
- 2High-Speed Transmission: Supports transmission speeds of 500 kbps.
- 3Robust Protection: Features IP20 degree of protection for reliable operation.
- 4Versatile Power Supply: Supplies 24 V DC voltage range (19.2 V DC to 30 V DC) for various applications.
- 5Diagnostic Indicators: Includes diagnostic and status indicators for easy monitoring and troubleshooting.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Width | 48.8 mm | Height | 135 mm |
| Depth | 71.5 mm | Note on dimensions | Housing dimensions |
| Color | green | No. of channels | 2 |
| Connection method | Inline shield connector | Transmission speed | 500 kbps |
| Transmission physics | Copper | Connection method | Inline data jumper |
| Transmission speed | 500 kbps | Number of local bus devices that can be connected | 63 |
| Number of devices with parameter channel | 62 | Number of supported branch terminals with remote bus branch | 0 (A terminal with remote bus branch cannot be used.) |
| ID code (dec.) | 04 | ID code (hex) | 04 |
| Length code (hex) | 00 | Length code (dec) | 00 |
| Process data channel | 0 bit | Input address area | 0 Byte |
| Output address area | 0 Byte | Register length | 0 bit |
| Product type | I/O component | Product family | Inline |
| Type | modular | Scope of delivery | including Inline connectors and marking fields |
| Supply voltage | 24 V DC (via Inline connector) | Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Current draw | max. 1.25 A (with max. number of connected I/O terminal blocks)
typ. 100 mA (no local bus devices connected) | Supply voltage | 7.5 V DC |
| Supply voltage | 24 V DC | Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Supply voltage | 24 V DC (via Inline connector) | Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Supply voltage | 24 V DC (via Inline connector) | Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) |
| Test voltage: 5 V supply, incoming remote bus / 5 V supply outgoing remote bus | 500 V AC, 50 Hz, 1 min | Test voltage: 5 V supply incoming remote bus / 7.5 V communications power, 24 V analog supply, 24 V bus coupler supply | 500 V AC, 50 Hz, 1 min |
| Test voltage: 5 V supply, incoming remote bus / 24 V main supply, 24 V segment supply | 500 V AC, 50 Hz, 1 min | Test voltage: 5 V supply incoming remote bus / functional ground | 500 V AC, 50 Hz, 1 min |
| Test voltage: 5 V supply outgoing remote bus / I/O (U | 500 V AC, 50 Hz, 1 min | Test voltage: 5 V supply outgoing remote bus / communications power (U | 500 V AC, 50 Hz, 1 min |
| Test voltage: 5 V supply outgoing remote bus / functional ground | 500 V AC, 50 Hz, 1 min | Test voltage: 7.5 V communications power, 24 V analog supply, 24 V bus coupler supply/functional ground | 500 V AC, 50 Hz, 1 min |
| Test voltage: Communications power (U | 500 V AC, 50 Hz, 1 min | Test voltage: 24 V main supply, 24 V segment supply/functional ground | 500 V AC, 50 Hz, 1 min |
| Connection name | Inline connector | Connection method | Spring-cage connection |
| Conductor cross section rigid | 0.09 mm² ... 1.5 mm² | Conductor cross section flexible | 0.09 mm² ... 1.5 mm² |
| Conductor cross section AWG | 28 ... 16 | Stripping length | 8 mm |
| Connection method | Spring-cage connection | Conductor cross section, rigid | 0.09 mm² ... 1.5 mm² |
| Conductor cross section, flexible | 0.09 mm² ... 1.5 mm² | Conductor cross section AWG | 28 ... 16 |
| Stripping length | 8 mm | Ambient temperature (operation) | -25 °C ... 55 °C |
| Degree of protection | IP20 | Air pressure (operation) | 80 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) | Ambient temperature (storage/transport) | -25 °C ... 85 °C |
| Permissible humidity (operation) | 75 % ... 85 % (in the range of -25°C ... +55°C, appropriate measures against increased humidity (> 85%) must be taken.) | Permissible humidity (storage/transport) | 75 % ... 85 % (Slight temporary condensation may sometimes appear on the housing, e.g. when the terminal block is brought out of a vehicle into an enclosed room.) |
| Protection class | III (IEC 61140, EN 61140, VDE 0140-1) | Mounting type | DIN rail mounting |
Specifications may be subject to change without notice