Product Model
ILC 350 PN

Key Features
- 1High-Performance PROFINET Interface: Seamlessly integrate with other controllers and systems via PROFINET.
- 2Modular Design: Highly modular design adaptable to various application requirements.
- 3IEC 61131-3 Programming: Program using PC WorX automation software according to IEC 61131-3 standards.
- 4Advanced Data Exchange: Exchange data with OPC servers and communicate with TCP/IP-compatible devices.
- 5Compact and Reliable: Compact size with a robust design, ensuring reliable operation in demanding environments.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Product type | Controller | Product family | Inline |
| Type | Inline format with alignable I/Os | Diagnostics display | no |
| Processor | PXA 255 400 MHz | Retentive data storage | 64 kByte (NVRAM) |
| Program memory | typ. 1 Mbyte | Data storage system | 2 Mbyte |
| Number of control tasks | 16 | Amount of process data | max. 8192 bit (INTERBUS) |
| Number of supported devices | max. 512 (in total, of which 254 are remote bus devices/bus segments) | Number of local bus devices that can be connected | max. 63 (observe current consumption) |
| Number of devices with parameter channel | max. 62 | Number of supported branch terminals with remote bus branch | 15 |
| Device function | PROFINET-Controller | Specification | Version 1.1 |
| Update rate | min. 1 ms | Diagnostics display | no |
| Controller redundancy | yes | Note on controller redundancy | applicative system redundancy possible |
| Safety function | no | Designation | LNK, ACT, 100 |
| Monitored function | Higher-level network | Optical representation | LED |
| Programming languages supported | Programming in acc. with IEC 61131-3 | Engineering tool | PC Worx |
| Diagnostics tool | DIAG+ from version 1.14 | Local diagnostics | LNK, ACT, 100 Higher-level network LED
FC RUN, FAIL IEC 61131 runtime system LED
RDY/RUN, BSA, FAIL, PF INTERBUS master LED |
| Transmission medium | Copper | Maximum power dissipation for nominal condition | max. 6 W |
| Supply voltage | 24 V DC ±5 % | Supply voltage range | 20.4 V DC ... 30 V DC |
| Residual ripple | ± 5 % | Typical current consumption | 250 mA (no local bus device connected during idling, bus inactive) |
| Realtime clock | Integrated (battery backup) | Supply voltage | 7.5 V DC ±5 % |
| Supply voltage | 24 V DC -15 % / +20 % | Supply voltage | 24 V DC -15 % / +20 % (in accordance with EN 61131-2) |
| Current draw | max. 8 A DC | Supply voltage | 24 V DC -15 % / +20 % (in accordance with EN 61131-2) |
| Current draw | max. 5 A | Input name | Digital inputs |
| Description of the input | Eight fast inputs, interrupt input | Number of inputs | 12 |
| Connection method | Inline potential distributor | Connection technology | 2-, 3-, 4-conductor |
| Output name | Digital outputs | Connection method | Spring-cage connection |
| Connection technology | 2-, 3-, 4-conductor | Number of outputs | 4 |
| Output voltage | 24 V DC | Maximum output current per channel | 500 mA |
| Connection method | Spring-cage connection | Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² |
| Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² | Conductor cross section AWG | 28 ... 16 |
| Web server | no | Bus system | RJ45 |
| Number of interfaces | 1 | Connection method | RJ45 jack |
| Transmission speed | 10/100 Mbps | No. of channels | 1 |
| Number of interfaces | 1 | Connection method | Inline data jumper |
| Transmission speed | 500 kBaud / 2 MBaud (can be switched) | Bus system | RS-232 |
| Number of interfaces | 1 | Connection method | 6-pos. MINI DIN socket (PS/2) |
| Transmission physics | Copper | No. of channels | 1 |
| Width | 182 mm | Height | 140.5 mm |
| Depth | 71.5 mm | Color | green (RAL 6021) |
| Degree of protection | IP20 | Ambient temperature (operation) | -25 °C ... 55 °C |
| Ambient temperature (storage/transport) | -25 °C ... 85 °C | Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) | Shock | 25g, Criterion 1, according to IEC 60068-2-27 |
| Vibration (operation) | 5g, accordance to IEC 60068-2-6 | Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) | Mounting type | DIN rail mounting |
Specifications may be subject to change without notice