Product Model
ILC 350 ETH/M

Key Features
- 1Adaptable to various application requirements with direct integration in Inline automation systems.
- 2Enables parameterization and programming using PC WorX automation software according to IEC 61131-3.
- 3Supports numerous protocols such as HTTP, FTP, SNTP, SNMP, SMTP, SQL, and MySQL.
- 4Meets maritime standards for use in harsh environments.
- 5Handles up to 8192 I/O points with support for INTERBUS and other fieldbus protocols.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Product type | Controller | Product family | Inline |
| Type | Inline format with alignable I/Os | Diagnostics display | no |
| Retentive data storage | 64 kByte (NVRAM) | Program memory | typ. 1 Mbyte |
| Data storage system | 2 Mbyte | Number of control tasks | 16 |
| Amount of process data | max. 8192 bit (INTERBUS) | Number of supported devices | max. 512 (in total, of which 254 are remote bus devices/bus segments) |
| Number of local bus devices that can be connected | max. 63 (observe current consumption) | Number of devices with parameter channel | max. 62 |
| Number of supported branch terminals with remote bus branch | 15 | Diagnostics display | no |
| Controller redundancy | no | Engineering tool | PC Worx |
| Diagnostics tool | DIAG+ from version 1.14 | Transmission medium | Copper |
| Maximum power dissipation for nominal condition | max. 6 VA | Supply voltage | 24 V DC ±5 % |
| Supply voltage range | 20.4 V DC ... 30 V DC | Residual ripple | ± 5 % |
| Typical current consumption | 250 mA (no local bus device connected during idling, bus inactive) | Realtime clock | Integrated (battery backup) |
| Supply voltage | 7.5 V DC ±5 % | Supply voltage | 24 V DC -15 % / +20 % |
| Supply voltage | 24 V DC -15 % / +20 % (in accordance with EN 61131-2) | Supply voltage | 24 V DC -15 % / +20 % (in accordance with EN 61131-2) |
| Current draw | max. 5 A | Input name | Digital inputs |
| Description of the input | Eight fast inputs, interrupt input | Number of inputs | 12 |
| Connection method | Inline potential distributor | Connection technology | 2-, 3-, 4-conductor |
| Output name | Digital outputs | Connection method | Spring-cage connection |
| Connection technology | 2-, 3-, 4-conductor | Number of outputs | 4 |
| Output voltage | 24 V DC | Maximum output current per channel | 500 mA |
| Connection method | Spring-cage connection | Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² |
| Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² | Conductor cross section AWG | 28 ... 16 |
| Number of interfaces | 1 | Connection method | Inline data jumper |
| Transmission speed | 500 kBaud / 2 MBaud (can be switched) | Bus system | RS-232 |
| Connection method | 6-pos. MINI DIN socket (PS/2) | Transmission speed | max. 38.4 kbps |
| Transmission physics | Copper | No. of channels | 1 |
| Bus system | RJ45 | Number of interfaces | 1 |
| Connection method | RJ45 jack | Transmission speed | 10/100 Mbps |
| No. of channels | 1 | Width | 182 mm |
| Height | 140.5 mm | Depth | 71.5 mm |
| Color | green (RAL 6021) | Degree of protection | IP20 |
| Ambient temperature (operation) | -25 °C ... 55 °C | Ambient temperature (storage/transport) | -25 °C ... 85 °C |
| Permissible humidity (operation) | 10 % ... 95 % (non-condensing) | Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) |
| Shock | 25g, Criterion 1, according to IEC 60068-2-27 | Vibration (operation) | 5g, accordance to IEC 60068-2-6 |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) | Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Mounting type | DIN rail mounting |
Specifications may be subject to change without notice