Key Features
- 1High-Speed Communication: Supports transmission speeds of up to 500 kbps for efficient data transfer.
- 2Diagnostic Indicators: Equipped with diagnostic and status indicators for easy monitoring and troubleshooting.
- 3Remote Bus Branch: Extends the INTERBUS network by opening remote bus branches, enhancing system scalability.
- 4Modular Design: Compatible with various Phoenix Contact branch terminals, allowing for flexible system integration.
- 5Durable Construction: Operates within a wide ambient temperature range (-25 °C to 85 °C) and humidity levels (10% to 95%).
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Width | 12.2 mm | Height | 135 mm |
| Depth | 71.5 mm | Note on application | Only for industrial use |
| Connection method | Inline data jumper | Transmission speed | 500 kbps |
| Connection method | Inline shield connector | Transmission speed | 500 kbps |
| Transmission physics | RS-485 | Connection method | Inline data jumper |
| Transmission speed | 500 kbps | Transmission physics | Copper |
| Number of local bus devices that can be connected | max. 63 (Consider the logic current consumed by the devices; the branch terminal does not count as an Inline station device.) | ID code (dec.) | 04 |
| ID code (hex) | 04 | Length code (hex) | 0 |
| Length code (dec) | 0 | Process data channel | 0 bit |
| Input address area | 0 Byte | Output address area | 0 Byte |
| Register length | 0 bit | Product type | I/O component |
| Product family | Inline | Type | modular |
| Scope of delivery | including Inline connector and labeling field | Special properties | with remote bus branch
Extreme conditions version |
| Article revision | 02 | Supply voltage | 24 V DC (via voltage jumper) |
| Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) | Current draw | typ. 29 mA |
| Test voltage: 5 V supply, incoming remote bus, 5 V supply outgoing remote bus, 5 V supply logic | 500 V AC, 50 Hz, 1 min | Test voltage: Remote bus branch | 500 V AC, 50 Hz, 1 min |
| Test voltage: Functional ground | 500 V AC, 50 Hz, 1 min | Connection name | Inline connector |
| Connection method | Spring-cage connection | Conductor cross section rigid | 0.08 mm² ... 1.5 mm² |
| Conductor cross section flexible | 0.08 mm² ... 1.5 mm² | Conductor cross section AWG | 28 ... 16 |
| Stripping length | 8 mm | Connection method | Spring-cage connection |
| Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² | Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² |
| Conductor cross section AWG | 28 ... 16 | Stripping length | 8 mm |
| Ambient temperature (operation) | -25 °C ... 55 °C
-40 °C ... 70 °C (Extended, see section “Tested successfully: use under extreme ambient conditions” in the data sheet.) | Degree of protection | IP20 |
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) | Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C | Permissible humidity (operation) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Permissible humidity (storage/transport) | 10 % ... 95 % (according to DIN EN 61131-2) | Protection class | III (IEC 61140, EN 61140, VDE 0140-1) |
| Mounting type | DIN rail mounting |