Product Model
IB IL 24 DO2-2A-2MBD

Key Features
- 1The IB IL 24 DO 2-2A-2MBD offers two digital outputs, each capable of handling 2 A of current.
 - 2Supports connection of actuators in 2-, 3-, and 4-wire technology for versatile application.
 - 3Equipped with short-circuit and overload protection for reliable operation.
 - 4Includes diagnostic and status indicators for easy monitoring and troubleshooting.
 - 5Measures 12.2 mm in width, 119.5 mm in height, and 71.5 mm in depth, making it compact and space-efficient.
 
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
| Parameter | Value | Parameter | Value | 
|---|---|---|---|
| Width | 12.2 mm  | Height | 119.8 mm  | 
| Depth | 71.5 mm  | Note on dimensions | Housing dimensions  | 
| EMC note | EMC: class A product, see manufacturer's declaration in the download area  | Color | green  | 
| Connection method | Inline data jumper  | Transmission speed | 2 Mbps  | 
| ID code (dec.) | 189  | ID code (hex) | BD  | 
| Length code (hex) | C2  | Length code (dec) | 194  | 
| Process data channel | 2 bit  | Input address area | 0 Byte  | 
| Output address area | 2 bit  | Register length | 2 bit  | 
| Output name | Digital outputs  | Connection method | Spring-cage connection  | 
| Connection technology | 2-, 3-, 4-conductor  | Number of outputs | 2  | 
| Protective circuit | Overload protection, short-circuit protection of outputs  | Output voltage | 24 V DC (via voltage jumper)  | 
| Maximum output current per channel | 2 A  | Maximum output current per module | 4 A  | 
| Nominal output voltage | 24 V DC (voltage difference at I  | Nominal load, inductive | 48 W  | 
| Nominal load, lamp | 48 W  | Nominal load, ohmic | 48 VA  | 
| Behavior with overload | Auto restart  | Behavior with inductive overload | Output can be destroyed  | 
| Behavior at voltage switch-off | The output follows the power supply without delay  | Product type | I/O component  | 
| Product family | Inline  | Type | modular
Inline  | 
| No. of channels | 2  | Diagnostics messages | Short-circuit or overload of the digital outputs Error message in the diagnostic code (bus) and display (2 Hz) via the LED (D) on the module  | 
| Supply voltage | 7.5 V DC (via voltage jumper)  | Current draw | max. 60 mA  | 
| Supply voltage | 24 V DC (via voltage jumper)  | Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple)  | 
| Current draw | max. 4 A  | Test voltage: 5 V supply, incoming remote bus/7.5 V supply (bus logics) | 500 V AC, 50 Hz, 1 min  | 
| Test voltage: 5 V supply, outgoing remote bus/7.5 V supply (bus logics) | 500 V AC, 50 Hz, 1 min  | Test voltage: 7.5 V supply (bus logics)/24 V supply (I/O) | 500 V AC, 50 Hz, 1 min  | 
| Test voltage: 24 V supply (I/O) / functional ground | 500 V AC, 50 Hz, 1 min  | Connection name | Inline connector  | 
| Connection method | Spring-cage connection  | Conductor cross section rigid | 0.08 mm² ... 1.5 mm²  | 
| Conductor cross section flexible | 0.08 mm² ... 1.5 mm²  | Conductor cross section AWG | 28 ... 16  | 
| Stripping length | 8 mm  | Connection method | Spring-cage connection  | 
| Conductor cross section, rigid | 0.08 mm² ... 1.5 mm²  | Conductor cross section, flexible | 0.08 mm² ... 1.5 mm²  | 
| Conductor cross section AWG | 28 ... 16  | Stripping length | 8 mm  | 
| Ambient temperature (operation) | -25 °C ... 55 °C  | Degree of protection | IP20  | 
| Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level)  | Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level)  | 
| Ambient temperature (storage/transport) | -25 °C ... 85 °C  | Permissible humidity (operation) | 10 % ... 95 % (according to DIN EN 61131-2)  | 
| Permissible humidity (storage/transport) | 10 % ... 95 % (according to DIN EN 61131-2)  | Protection class | III (IEC 61140, EN 61140, VDE 0140-1)  | 
| Mounting type | DIN rail mounting  | 
Specifications may be subject to change without notice