Product Model
IB IL 24 DI8/HD-2MBD-PAC

Key Features
- 1Process up to 8 digital signals with this versatile terminal.
- 2Operate with 24 V DC, ensuring reliable digital signal acquisition.
- 3Efficiently transmit data at 500 kbps for smooth operations.
- 4Designed with IP20 protection for safe and durable use in industrial settings.
- 5Includes diagnostic and status indicators for easy monitoring and troubleshooting.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Width | 12.2 mm | Height | 119.8 mm |
| Depth | 71.5 mm | EMC note | EMC: class A product, see manufacturer's declaration in the download area |
| Connection method | Inline data jumper | Transmission speed | 2 Mbps |
| ID code (dec.) | 190 | ID code (hex) | BE |
| Length code (hex) | 81 | Length code (dec) | 129 |
| Process data channel | 8 bit | Input address area | 1 Byte |
| Output address area | 0 Byte | Register length | 8 bit |
| Required parameter data | 1 Byte | Required configuration data | 4 Byte |
| Input name | Digital inputs | Description of the input | EN 61131-2 types 1 and 3 |
| Number of inputs | 8 | Connection method | Spring-cage connection |
| Connection technology | 1-conductor | Input voltage | 24 V DC |
| Input voltage range "0" signal | -3 V DC ... 5 V DC | Input voltage range "1" signal | 11 V DC ... 30 V DC |
| Nominal input voltage U | 24 V DC | Nominal input current at U | typ. 2.4 mA |
| Typical input current per channel | 2.4 mA | Typical response time | 1 ms |
| Delay at signal change from 0 to 1 | 1 ms | Delay at signal change from 1 to 0 | 1 ms |
| Product type | I/O component | Product family | Inline |
| Type | modular | Scope of delivery | including Inline connector and labeling field |
| No. of channels | 8 | Operating mode | Process data mode with one byte |
| Maximum power dissipation for nominal condition | 24.12 W | Supply voltage | 7.5 V DC (via voltage jumper) |
| Current draw | max. 30 mA | Supply voltage | 24 V DC (via voltage jumper) |
| Supply voltage range | 19.2 V DC ... 30 V DC (including all tolerances, including ripple) | Current draw | max. 5.5 mA |
| Test voltage: 5 V supply, incoming remote bus/7.5 V supply (bus logics) | 500 V AC, 50 Hz, 1 min | Test voltage: 5 V supply, outgoing remote bus/7.5 V supply (bus logics) | 500 V AC, 50 Hz, 1 min |
| Test voltage: 7.5 V supply (bus logics)/24 V supply (I/O) | 500 V AC, 50 Hz, 1 min | Test voltage: 24 V supply (I/O) / functional ground | 500 V AC, 50 Hz, 1 min |
| Connection name | Inline connector | Connection method | Spring-cage connection |
| Conductor cross section rigid | 0.08 mm² ... 1.5 mm² | Conductor cross section flexible | 0.08 mm² ... 1.5 mm² |
| Conductor cross section AWG | 28 ... 16 | Stripping length | 8 mm |
| Connection method | Spring-cage connection | Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² |
| Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² | Conductor cross section AWG | 28 ... 16 |
| Stripping length | 8 mm | Ambient temperature (operation) | -25 °C ... 55 °C |
| Degree of protection | IP20 | Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) | Ambient temperature (storage/transport) | -25 °C ... 85 °C |
| Permissible humidity (operation) | 10 % ... 95 % (according to DIN EN 61131-2) | Permissible humidity (storage/transport) | 10 % ... 95 % (according to DIN EN 61131-2) |
| Protection class | III (IEC 61140, EN 61140, VDE 0140-1) | Mounting type | DIN rail mounting |
Specifications may be subject to change without notice