Product Model
FLT-PLUS CTRL-3.0/I

Key Features
- 1Compact design: 35.5 mm width, 150 mm height, and 80.5 mm depth.
- 2High reliability: V0 flammability rating according to UL 94.
- 3Versatile application: Compatible with CQM1 PLC and 16-point contact output.
- 4Enhanced protection: Surge arrestor/suppressor for reliable electrical protection.
- 5Cost-effective solution: Available for purchase as a surplus item starting at £149.14.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Product type | Combination type | IEC test classification | I
T1 |
| EN type | T1 | IEC power supply system | TT
TN-C
TN-S
IT |
| Type | DIN rail module, one-piece | Number of positions | 1 |
| Surge protection fault message | optical | Overvoltage category | III |
| Pollution degree | 2 | Nominal frequency f | 50 Hz
60 Hz |
| Nominal voltage U | 230 V AC (400 V AC) | Connection method | Screw connection |
| Screw thread | M6 | Tightening torque, min | 8 Nm |
| Stripping length | 19 mm | Conductor cross section flexible min. | 16 mm² |
| Conductor cross section flexible max. | 35 mm² | Conductor cross section, rigid min. | 10 mm² |
| Conductor cross section, rigid max. | 50 mm² | Width | 35.5 mm |
| Height | 150 mm | Depth | 80.5 mm |
| Horizontal pitch | 2 Div. | Flammability rating according to UL 94 | V0 |
| Housing material | PA-GF | Open side panel | No |
| Direction of action | 1L-N/PE | Nominal frequency f | 50 Hz
60 Hz |
| Maximum continuous voltage U | 440 V AC | Maximum continuous operating voltage U | 440 V AC |
| Maximum continuous operating voltage U | 440 V AC | Residual current I | ≤ 3 mA |
| Standby power consumption P | ≤ 1.32 VA | Nominal discharge current I | 50 kA |
| Nominal discharge current I | 50 kA | Nominal discharge current I | 50 kA |
| Maximum discharge current I | 50 kA | Impulse discharge current (10/350) µs, charge | 25 As |
| Impulse discharge current (10/350) µs, specific energy | 625 kJ/Ω | Impulse discharge current (10/350) µs, peak value l | 50 kA |
| Follow current interrupt rating I | 25 kA (440 V AC)
50 kA (350 V AC) | Voltage protection level U | ≤ 3 kV |
| Voltage protection level U | ≤ 3 kV | Voltage protection level U | ≤ 3 kV |
| Front of wave sparkover voltage at 6 kV (1.2/50) µs | ≤ 3 kV | Response time t | ≤ 100 ns |
| Response time t | ≤ 100 ns | Response time t | ≤ 100 ns |
| Max. backup fuse with branch wiring | 500 A (NH-gL) | Degree of protection | IP20 |
| Ambient temperature (operation) | -40 °C ... 85 °C | Permissible humidity (operation) | ≤ 95 % |
| Standards/regulations | EN 60664-1 / EN 61643-11 | Standards/regulations | IEC 61643-1
DIN EN 61643-11
DIN EN 61643-11/A11 |
| Standards/specifications | IEC 61643-1 | Note | 2005 |
| Standards/specifications | DIN EN 61643-11 | Note | 2002 |
| Standards/specifications | DIN EN 61643-11/A11 | Note | 2007 |
| Mounting type | DIN rail: 35 mm |