Product Model
FL NAT 2304-2GC-2SFP

Key Features
- 1High-Speed Connectivity: Supports 10/100/1000 Mbps on RJ45 ports and 100/1000 Mbps on SFP ports.
- 2Flexible Port Options: Includes 4 RJ45 ports, 2 SFP ports, and 2 combo ports for versatile connectivity.
- 3Advanced Networking Features: Compliant with IEEE 802.3, supports RSTP, MRP, and LACP for robust network management.
- 4Industrial-Grade Reliability: Designed for extended temperature range (-40°C to 70°C) and high humidity environments.
- 5Secure and Manageable: Offers port security, MAC-based authentication, and web-based management via HTTP/HTTPS.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Width | 45 mm | Height | 130 mm |
| Depth | 115 mm | General | Support by phone or on-site (fee is charged) |
| Note on application | Only for industrial use | Housing material | Polycarbonate fiber reinforced |
| Mounting type | DIN rail mounting | Connection method | RJ45 |
| Note on the connection method | Auto negotiation and autocrossing | Transmission speed | 10/100/1000 Mbps |
| Transmission physics | Copper | Transmission length | 100 m (per segment) |
| Signal LEDs | Data receive, link status | No. of channels | 4 (RJ45 ports) |
| Number of interfaces | 2 | Connection method | SFP |
| Transmission speed | 100/1000 Mbps (full duplex) | Transmission physics | Depending on the SFP module |
| Transmission length | up to 80 km (Depending on the fiber/SFP module used) | Signal LEDs | Data receive, link status |
| No. of channels | 2 (SFP ports) | Number of interfaces | 2 |
| Connection method | SFP/RJ45 | Note on the connection method | Auto negotiation and autocrossing |
| Transmission speed | 10/100/1000 Mbps (full duplex) | Transmission physics | Depending on the SFP module |
| Transmission length | up to 80 km (Depending on the fiber/SFP module used) | Signal LEDs | Data receive, link status |
| No. of channels | 2 (Combo ports) | Output name | Alarm output |
| Product type | Switch | Product family | Managed NAT Switch 2000 |
| Type | Book type | MTTF | 362.94 Years (SN 29500 standard, temperature 25°C, operating cycle 21%)
158.13 Years (SN 29500 standard, temperature 40°C, operating cycle 34.25%)
19.77 Years (SN 29500 standard, temperature 70°C, operating cycle 100%) |
| Special properties | 1:1-NAT, Virtual NAT, IP-Masquerading
Development process certified in accordance with IEC 62443-4-1
Compatible with IEC 62443-4-2 | Signal delay | ≥ 1.9 µs (Store-and-Forward mode, 10/100/1000 Mbps, depending on the frame size) |
| Article revision | 05 | Protection class | III (VDE 0106) |
| Degree of pollution | 2 | Diagnostic functions | RMON History
LLDP (Link Layer Discovery Protocol)
SNMP-Traps
N:1-Portmirroring
ACD (Address Conflict Detection)
SysLog
CRC-Surveillance |
| Basic functions | Store-and-forward switch, complies with IEEE 802.3 | Signal contact control voltage | typ. 24 V DC |
| NAT functions | 1:1-NAT
Virtual-NAT
IP-Masquerading
Port forwarding | PROFINET conformance class | Conformance-Class B |
| PROFINET device function | PROFINET device | Filter functions | Quality of Service (8 priority classes)
Class of Service
DiffServ/DSCP
Port-Priorisierung
VLAN (up to 32 VLANs)
IGMP Snooping/Querier (v1/v2)
Auto-Query-Port
Extended Multicast Filtering |
| IP parameterization | DHCP client
DHCP Option 82 (Relay Agent)
DHCP server (pool-based, port-based)
BootP
DCP (Discovery and Configuration Protocol) | MAC address table | 8k |
| Management | Web-based management (HTTP/HTTPS)
Role-based user management (LDAP, RADIUS)
SNMPv1/v2/v3
Command Line Interface (Telnet, SSH) | Redundancy | MRP (Media Redundancy Protocol)
RSTP (Rapid Spanning Tree Protocol)
FRD (Fast Ring Detection)
Large Tree Support
LACP (Link Aggregation Control Protocol)
PROFINET S2 system redundancy |
| Status and diagnostic indicators | LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (Link/Activity and Speed) | Additional functions | Jumbo frames (max. 9,600 bytes) |
| Time synchronization | SNTP (Simple Network Time Protocol) | Port security | MAC-based, RADIUS (IEEE 802.1X), MAC Authentication Bypass |
| Basic functions | Store-and-forward switch, complies with IEEE 802.3 | Current consumption | 290 mA |
| Local diagnostics | US1/2 Supply voltage US1, US2 Green LED
FAIL Div. LED red
LINK Link status Green LED | Maximum power dissipation for nominal condition | 9 W (At U |
| Test section | 500 V DC 1 min | Transmission medium | Copper
FO |
| Supply voltage (DC) | 24 V DC (redundant) | Supply voltage range | 12 V DC ... 57 V DC |
| Power supply connection | via COMBICON, max. conductor cross section 1.5 mm² | Residual ripple | 3.6 V |
| Max. current consumption | 1.5 A (U | Typical current consumption | 290 mA (at U |
| Current consumption | 290 mA | Signal contact control voltage | typ. 24 V DC |
| Connection method | Screw connection | Note on the connection method | Use only copper connecting cables providing the permitted temperature range (-40 °C ... 75 °C). |
| Conductor cross section, rigid | 0.08 mm² ... 1.5 mm² | Conductor cross section, flexible | 0.08 mm² ... 1.5 mm² |
| Conductor cross section AWG | 28 ... 16 | Stripping length | 7 mm |
| Degree of protection | IP20 | Ambient temperature (operation) | -40 °C ... 70 °C |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C | Permissible humidity (operation) | 10 % ... 95 % (non-condensing) |
| Permissible humidity (storage/transport) | 10 % ... 95 % (non-condensing) | Shock (operation) | 30g (EN 60068-2-27) |
| Vibration (operation) | in acc. with IEC 60068-2-6: 5g, 150 Hz | Air pressure (operation) | 80 kPa ... 110 kPa up to 2000 m above mean sea level (Without derating) |
| Air pressure (storage/transport) | 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) | Free from substances that could impair the application of coating | Yes |
| Identification | II 3 G Ex ec IIC T4 Gc | Certificate | DEMKO 16 ATEX 1709X |
| References to standards | EN 60079-0
EN 60079-7 | Identification | Ex ec IIC T4 Gc |
| Certificate | IECEx ULD 16.0018 X | References to standards | IEC 60079-0
IEC 60079-7 |
| Identification | cULus | Identification | Class I, Division 2, Groups A, B, C, and D, T4
Class I, Zone 2, AEx ec IIC T4
Ex ec IIC T4 Gc X |
| Certificate | E366272 | Note | UL 60079-0 Ed. 6 / UL 60079-7 Ed. 5, CSA 22.2 No. 60079-0 Ed. 3 / CSA C22.2 No. 60079-7 Ed. 2 |
| Identification | 2Ex e IIC T4 Gc X | Certificate | RU C-DE.HB49.B.00118/21 |
| Identification | Install the device in a suitable, approved housing with at least IP66 protection.
The housing/control cabinet must be equipped with a warning sign prohibiting opening in the potentially explosive area.
The operation of devices is permitted if all optical ports are connected or sealed with the supplied filler plugs. | Identification | Ex ec IIC T4 Gc |
| Certificate | 2022122310115629 | Identification | ISA S71.04.2013 G3 Harsh Group A |
| Identification | II 3 G Ex ec IIC T4 Gc | Certificate | PxCIMA22UKEX2702910X |
| Temperature | B | Humidity | B |
| Vibration | A | EMC | B |
| Enclosure | Required protection according to the Rules shall be provided upon installation on board | Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Conformance with EMC directives | EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B
EN 61000-6-2 EN 61000-4-3 (electromagnetic fields) Criterion A
EN 61000-6-2 EN 61000-4-4 (EFT burst) Criterion A
EN 61000-6-2 EN 61000-4-5 (surge) Criterion A
EN 61000-6-2 EN 61000-4-6 (line noise immunity) Criterion A
EN 61000-6-2 EN 61000-6-4 (interference) Class A
EN 61000-6-2 EN 61000-6-4 (conducted interference) Class A | Noise immunity | EN 61000-6-2 |
| Noise emission | EN 61000-6-4 | Basic functions | Store-and-forward switch, complies with IEEE 802.3 |
| Status display | LEDs: US1, US2 (power supply), Fail (alarm contact), 2 LEDs per Ethernet port (Link/Activity and Speed) |
Specifications may be subject to change without notice