Product Model
FLK-MIL50/EZ-DR/KS/3500/YCS

Key Features
- 1Assembled with tin-plated Cu litz wires for superior signal integrity.
- 2Specifically designed for Yokogawa CS3000 CentumVP (ADV561, ADV161) controllers.
- 3Operates within -10°C to 70°C for flexible installations and -40°C to 70°C for fixed installations.
- 4Supports up to 500 mA per path with an operating voltage of ≤30 V DC.
- 5Meets IEC 60332-1-2 and UL VW-1 flame resistance standards for reliable performance.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Product type | System cable | Article revision | 07 |
| Degree of protection | IP00 | Degree of protection (Installation location) | ≥ IP54 (Installation location) |
| Ambient temperature (operation) | -40 °C ... 70 °C (fixed installation)
-10 °C ... 70 °C (flexible installation) | Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Altitude | ≤ 2000 m | Operating voltage (DC) | ≤ 30 V DC |
| Nominal operating mode | 100% operating factor | Current (Per path) | ≤ 500 mA (uncoiled) |
| Suitable I/O card | ADV161
ADV561 | Suitable I/O card | NFDV161
NFDV561 |
| Cable length | 35 m | UL AWM Style | 2464/1061 |
| Number of positions | 50 | Shielded | yes |
| Cable type | 50X0.14 [PVC] | Conductor type | Assembled shielded round cable |
| Conductor structure signal line | 7x 0.16 mm | AWG signal line | 26 |
| Conductor cross section | 50x 0.14 mm² | Wire diameter incl. insulation | 1 mm ±0.03 mm |
| External cable diameter | 11.00 mm ±0.3 mm | Outer sheath, material | Semi-rigid PVC |
| External sheath, color | gray | Conductor material | Tin-plated Cu litz wires |
| Cable resistance | ≤ 145 Ω/km (at 20 °C) | Insulation resistance | ≥ 20 MΩ*km (20 °C) |
| Smallest bending radius, fixed installation | 114 mm | Smallest bending radius, movable installation | 205 mm |
| Dynamic load capacity (bending) | Max. bending cycles: 5000 (at a radius of ≥ 18x outside diameter) | Halogen-free | no |
| Flame resistance | IEC 60332-1-2 (raw cable)
VDE 0842, Part 332-1-2 (raw cable)
IEC 60332-3-22 (raw cable)
UL VW-1
CSA FT-1 | Resistance to oil | can withstand occasional splashes (raw cable) |
| Connection in acc. with standard | IEC 60603-13 (in compliance) | Connection method | IDC/FLK socket strip |
| Number of connections | 1 | Number of positions | 50 |
| Insertion/withdrawal cycles | > 50 | Pitch | 2.54 mm |
| Connection in acc. with standard | IEC 60603-13 (in compliance) | Connection method | Yokogawa, KS compatible |
| Number of connections | 1 | Number of positions | 50 |
| Tightening torque | 0.5 Nm (Screw connection) | Insertion/withdrawal cycles | > 50 |
| Pitch | 2.54 mm | Connection method | Screw connection |
| Tightening torque | 0.5 Nm | Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
Specifications may be subject to change without notice