Product Model
FLKM-2FLK14/SI/DIO/AI8

Key Features
- 1Compatible with Siemens S7-300 and GE-FANUC systems, ensuring seamless integration.
- 2Features functional insulation and overvoltage category II, ensuring reliable operation in harsh environments.
- 3Offers 14 positions with 16 channels, allowing for customizable configurations to meet specific needs.
- 4Built with PVC housing and designed for insertion/withdrawal cycles > 50, ensuring long-lasting performance.
- 5Features screw connection with disconnect knife and test socket connections, simplifying the installation process.
Technical Specifications
Detailed engineering parameters based on manufacturer documentation
| Parameter | Value | Parameter | Value |
|---|---|---|---|
| Product type | Interface module | No. of channels | 8 |
| Overvoltage category | II | Pollution degree | 2 |
| Nominal voltage U | 24 V DC | Max. current carrying capacity per branch | 1 A |
| Max. total current of all branches | 2 A | Max. total current of voltage supply | 2 A |
| Suitable I/O card | 6ES7331-7KF02-0AB0
6ES7331-7NF00-0AB0 | Connection method | Spring-cage connection |
| Stripping length | 7.5 mm | Conductor cross section rigid | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible | 0.2 mm² ... 1.5 mm² | Conductor cross section AWG | 24 ... 14 |
| Connection method | IDC/FLK pin strip | Number of positions | 28 |
| Pitch | 2.54 mm | Status display | LED (green) |
| Status display present | Yes | Width | 90 mm |
| Height | 112.5 mm | Depth | 76 mm |
| Color | green (RAL 6021) | Housing insulation material | PVC |
| Ambient temperature (operation) | -20 °C ... 50 °C | Ambient temperature (storage/transport) | -20 °C ... 70 °C |
| Standards/regulations | DIN EN 50178 | Mounting type | DIN rail mounting |
| Assembly note | in rows with zero spacing | Mounting position | any |
| Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
Specifications may be subject to change without notice